Skip to main content

Audio cabling

Keyman 🔑 Crew
Lacey Cox Ruben Martinez; Zabrina Bourgeois; Karina Li; Bethany Mundell; Layo Kirby; TaSanee Kirby; Mike Mundell; Ronan Gav Budd; Meyana Barnhart

Your team runs, labels and protects the audio cables. Loudspeakers places the speakers, Stage handles cables on the stage with you, and Power runs all electrical cables.

Before starting, meet Lacey, review the team's DC-83, and open the schematics. Wear work shoes and gloves. Keep exits clear and cover every floor crossing.

Main reference — Sheet 1-1: seating and loudspeaker layout

Use Sheet 1-1 as the main reference for the A/V booth, loudspeaker positions and cable destinations.

CABR-2026 Sheet 1-1 showing the seating area, A/V booth and loudspeaker positions

🗺️ View venue layout — departments and room orientation

Use this only to orient yourself to departments, partitions and room features. Use the CABR schematics for A/V placement.

Imperial World Samrong circuit assembly venue layout showing departments and partitions

🔌 View Sheet 6-2 — loudspeaker wiring and splitters

There are two speakON splitters: LSCS-01 feeds the front loudspeaker group and LSCS-02 feeds the rear loudspeaker group.

CABR-2026 Sheet 6-2 showing LSCS-01 and LSCS-02 speakON splitters and loudspeaker wiring

What your team does

  1. Start at the stage and carefully lay the AMC-3 main audio cable toward the A/V booth. It is 30 m long; avoid sharp bends and protect its plugs.
  2. Run the labelled speaker cables to the six passive-speaker positions with the Loudspeakers team. LSCS-01 and LSCS-02 are the two speakON splitters: LSCS-01 serves the front group and LSCS-02 serves the rear group. Leave enough slack and hand over each cable before the speaker is raised.
  3. Run the two active-speaker lines: return A for the stage monitors and return B for the lobby and Accounting.
  4. Work with Stage to run the four microphone cables to AMC-3 inputs 1–4. Label each cable at the stage box and near the microphone.
  5. Run the venue wireless-microphone receivers to inputs 5–6.
  6. Cover all crossings with cable covers, mats or carpet. Hand the labelled ends to the A/V Booth, Stage and Loudspeaker teams, then help trace any line that fails its test.

Safety:
Accounting is beside the baptism area. Agree the route with the Baptism overseer and keep every cable away from wet floors.

For the keyman

Run Route Drawing
AMC-3 Stage box to AHEC-2 at the booth 4-1, 6-1
Front speakers Amplifier A → LSCS-01 (speakON splitter) → SPK-1.1 / 1.2 → 1.3 1-1, 6-2
Rear speakers Amplifier B → LSCS-02 (speakON splitter) → SPK-2.1 / 2.2 → 2.3 1-1, 6-2
Stage monitors AMC-3 return A → Stage Left → Stage Right 4-1, 6-2
Lobby / Accounting AMC-3 return B → Lobby → Accounting 6-2

When the routes are protected and the line tests pass, tell Lacey and Alex. Sunday teardown assignments will be added later; wait for the teardown briefing before removing anything.